Hi,
In my understanding, the EFlowTrack doesn't not include muons, because muons don't lose energy in the calorimeter. In the Delphes3. 0.2, delphes_card_default.dat in MadGraph Template contain eflowTrack, eFlowtower, eflowmuons, they are the default input for the jet reconstruction and the lepton isolation. But in the newest version Delphes 3.1.2, eflowtower is replaced by eflowphoton and eflowneutralhadron. It seems that the muons are not used for the jet reconstruction. Is there something I am missing? If not,
where not include the muons?
Best wishes,
Da Liu
Change History (4)
follow-up: 2 comment:1 by , 9 years ago
comment:2 by , 9 years ago
Hi,
Thanks a lot. Another question, what is the unit of the vertex positon for the track in the Delphes output? Is it in micrometer?
Best wishes,
Da Liu
Replying to mselvaggi:
Hi,
muons are now contained the eflowTrack collection.
Michele
comment:4 by , 9 years ago
Replying to mselvaggi:
The vertex position is in millimeters.
Thank you very much.
Best wishes,
Da Liu