142 | | >>> both figures |
| 142 | >>> the whole analysis has been re-done with the new implementation of the energy-flow algorithm. The discrepancy in the top mass resolution is not present anymore, |
| 143 | >>> the reason being that the resolution of the new energy-flow jets matches almost exaclty that of the CMS particle-flow jets at the energy of interest ( 60 GeV ). |
| 144 | >>> We attribute therefore the small discrepancy that was previously observed to the imperfect implementation of the previous particle-flow algorithm rather than to the absence of pile-up simulation. |
| 145 | >>> The whole sentence mentioning the discrepancy has been dropped, since the discrepancy is not present anymore. |