Fork me on GitHub

Changes between Initial Version and Version 1 of Ticket #844, comment 10


Ignore:
Timestamp:
Jan 27, 2016, 2:36:41 PM (9 years ago)
Author:
Alexandre Mertens

Legend:

Unmodified
Added
Removed
Modified
  • Ticket #844, comment 10

    initial v1  
    11Another possibility, and I think it is the issue you are looking for, is that by default, electrons and muons are included in the eflow collection, which is then used for the isolation computation.
    22
    3 Then is two leptons are close to each other, at least one of the two leptons won't be isolated.
    4 So, the procedure would be to create an extra collection (i.e. isoobjects) is it is done in the Energy flow merger but removing the tracks. And then use this collection as IsolationInputArray for the electrons and muons isolation.
     3Then if two leptons are close to each other, at least one of the two leptons won't be isolated.
     4So, the procedure would be to create an extra collection (i.e. isoobjects) as it is done in the Energy flow merger but removing the tracks as input. And then use this collection as IsolationInputArray for the electrons and muons isolation.
    55