    11Hello,
    22
    3 The efficiency for Electron (pT > 10 and abs(eta) < 2.5) is set at 95 % in the default CMS card. Nevertheless, there is an extra isolation criteria that might causes the difference.
     3The efficiency for Electron (pT > 10 and abs(eta) < 1.5) is set at 95 % and (pT > 10 and  1.5 < abs(eta) < 2.5) at 85 % in the default CMS card. Nevertheless, there is an extra isolation criteria that might causes the difference.
    44
    55How did you compute the "70%" you obtained?