Changeset 1cefce3 in git
- Timestamp:
- Sep 4, 2017, 8:37:17 PM (7 years ago)
- Branches:
- ImprovedOutputFile, Timing, dual_readout, llp, master
- Children:
- 22138b0
- Parents:
- 6990c60
- Location:
- cards/CMS_PhaseII
- Files:
-
- 5 edited
Legend:
- Unmodified
- Added
- Removed
-
cards/CMS_PhaseII/CMS_PhaseII_0PU_v02.tcl
r6990c60 r1cefce3 1336 1336 # set EfficiencyFormula {efficiency formula as a function of eta and pt} 1337 1337 # efficiency formula for electrons 1338 # efficiency for low pT leptons is set artifically to 100%. Analyzers should rescale according to proper lepton Id 1338 1339 set EfficiencyFormula { 1339 # efficiency for low pT leptons is set artifically to 100%. Analyzers should rescale according to proper lepton Id1340 1340 (pt <= 4.0) * (1.00) + \ 1341 1341 (abs(eta) <= 1.45 ) * (pt > 4.0 && pt <= 6.0) * (0.50) + \ … … 1381 1381 # set EfficiencyFormula {efficiency formula as a function of eta and pt} 1382 1382 # efficiency formula for electrons 1383 # efficiency for low pT leptons is set artifically to 100%. Analyzers should rescale according to proper lepton Id 1383 1384 set EfficiencyFormula { 1384 # efficiency for low pT leptons is set artifically to 100%. Analyzers should rescale according to proper lepton Id1385 1385 (pt <= 4.0) * (1.00) + \ 1386 1386 (abs(eta) <= 1.45 ) * (pt > 4.0 && pt <= 6.0) * (0.50) + \ -
cards/CMS_PhaseII/CMS_PhaseII_140PU_v02.tcl
r6990c60 r1cefce3 1336 1336 # set EfficiencyFormula {efficiency formula as a function of eta and pt} 1337 1337 # efficiency formula for electrons 1338 # efficiency for low pT leptons is set artifically to 100%. Analyzers should rescale according to proper lepton Id 1338 1339 set EfficiencyFormula { 1339 # efficiency for low pT leptons is set artifically to 100%. Analyzers should rescale according to proper lepton Id1340 1340 (pt <= 4.0) * (1.00) + \ 1341 1341 (abs(eta) <= 1.45 ) * (pt > 4.0 && pt <= 6.0) * (0.50) + \ … … 1381 1381 # set EfficiencyFormula {efficiency formula as a function of eta and pt} 1382 1382 # efficiency formula for electrons 1383 set EfficiencyFormula {# efficiency for low pT leptons is set artifically to 100%. Analyzers should rescale according to proper lepton Id1384 1383 # efficiency for low pT leptons is set artifically to 100%. Analyzers should rescale according to proper lepton Id 1384 set EfficiencyFormula { (pt <= 4.0) * (1.00) + \ 1385 1385 (abs(eta) <= 1.45 ) * (pt > 4.0 && pt <= 6.0) * (0.50) + \ 1386 1386 (abs(eta) <= 1.45 ) * (pt > 6.0 && pt <= 8.0) * (0.70) + \ -
cards/CMS_PhaseII/CMS_PhaseII_200PU_v02.tcl
r6990c60 r1cefce3 1335 1335 # set EfficiencyFormula {efficiency formula as a function of eta and pt} 1336 1336 # efficiency formula for electrons 1337 # efficiency for low pT leptons is set artifically to 100%. Analyzers should rescale according to proper lepton Id 1337 1338 set EfficiencyFormula { 1338 # efficiency for low pT leptons is set artifically to 100%. Analyzers should rescale according to proper lepton Id1339 1339 (pt <= 4.0) * (1.00) + \ 1340 1340 (abs(eta) <= 1.45 ) * (pt > 4.0 && pt <= 6.0) * (0.50) + \ … … 1380 1380 # set EfficiencyFormula {efficiency formula as a function of eta and pt} 1381 1381 # efficiency formula for electrons 1382 # efficiency for low pT leptons is set artifically to 100%. Analyzers should rescale according to proper lepton Id 1382 1383 set EfficiencyFormula { 1383 # efficiency for low pT leptons is set artifically to 100%. Analyzers should rescale according to proper lepton Id1384 1384 (pt <= 4.0) * (1.00) + \ 1385 1385 (abs(eta) <= 1.45 ) * (pt > 4.0 && pt <= 6.0) * (0.50) + \ -
cards/CMS_PhaseII/muonLooseId.tcl
r6990c60 r1cefce3 1 1 # tracking + LooseID efficiency formula for muons 2 # efficiency for low pT leptons is set artifically to 100%. Analyzers should rescale according to proper lepton Id 2 3 set EfficiencyFormula { 3 4 # efficiency for low pT leptons is set artifically to 100%. Analyzers should rescale according to proper lepton Id5 4 (pt <= 5.0) * (1.00) + \ 6 5 (pt > 5 && pt < 10) * (abs(eta) > 0 && abs(eta) < 0.2) * 0.967 + \ -
cards/CMS_PhaseII/muonTightId.tcl
r6990c60 r1cefce3 1 1 # tracking + TightID efficiency formula for muons 2 # efficiency for low pT leptons is set artifically to 100%. Analyzers should rescale according to proper lepton Id 2 3 set EfficiencyFormula { 3 4 # efficiency for low pT leptons is set artifically to 100%. Analyzers should rescale according to proper lepton Id5 4 (pt <= 5.0) * (1.00) + \ 6 5 (pt > 5 && pt < 10) * (abs(eta) > 0 && abs(eta) < 0.2) * 0.949 + \
Note:
See TracChangeset