Version 25 (modified by 13 years ago) ( diff ) | ,
---|
CMS Detector Card for Delphes
Detector fiducial acceptance
- tracker : eta <= 2.5
- calorimeter (barrel) : eta <= 1.7
- calorimeter (end-cap) : eta <= 3.0
- calorimeter (fordward) : eta <= 5.0
- muon chamber : eta < 2.4
Hadronic calorimeter
sigma/E = C + N/E + S/\sqrt{E}, E in GeV
Electromagnetic calorimeter
sigma/E = C + N/E + S/\sqrt{E}, E in GeV
Muon smearing
Tracker
Tracker PT min =
Tracker efficiencies
TRACK_radius 129 radius of the BField coverage, in cm
TRACK_length 300 half-length of the BField coverage, in cm
TRACK_bfield_x 0 X component of the BField, in T
TRACK_bfield_y 0 Y component of the BField, in T
TRACK_bfield_z 3.8 Z component of the BField, in T
Isolation criteria for leptons
PT thresholds
Jet reconstruction algorithm
B-tagging
Delphes describes b-tagging algorithms through 4 functions of two variables pT (x) and Eta (y) :
- b-tagging efficiencies
Function extracted from
Function extracted from BTV11-001 Figure 3 (a)
[K] * pow([alpha]*x,[beta]) / ( 1 + pow([alpha]*x,[beta]) )
K = 0.828
alpha = 0.048
beta = 2.386
- mistag for c-jets
Function extracted from BTV-09-001 Figure 6 (right)
[0]*x*exp ( [1]*x4 + [2]*x2 + [3]*x + [4] )
[0]=0.40
[1]=-2.19
[2]=2.79
[3]=3.01
[4]=-2.70
- mistag for gluon-jets and light-jets
Function extracted from BTV-09-001 Figure 6 (right)
[0]*x*exp ( [1]*x6 + [2]*x5 + [3]*x4 + [4]*x3 + [5]*x2 + [6]*x + [7] )
[0]= 0.0036
[1]= -78.22
[2]= 129.81
[3]=-44.16
[4]=-4.13
[5]=0.49
[6]=1.25
[7]=0.59
Attachments (1)
- accept.gif (23.8 KB ) - added by 13 years ago.
Download all attachments as: .zip