= Section 5 = The suggestion is to remove this section altogether. It is not detailed enough to be useful to a potential user (in contrast to a user manual), there is also not enough information to understand how things are truly implemented, but it still contains details irrelevant for a publication in JHEP. >>> The section 5 has been moved to the appendix. The authors believe that it is important that the information contained in this section, although very basic, >>> appears in the official Delphes public. For the reader it important to know which dataformat can be used as an input to Delphes, how the data-flow works, and finally, >>> what are the basic performances in terms of speed and memory usage, especially true for a "fast-simulation software". PAGE 11 Figure 1 is a striking illustration of the previous comment. This diagram is both too detailed for a JHEP publication, but too simplistic and not readable. For example: * there is no mention of PF, which is an important addition in DELPHES3 >>>added * there is no mention of PU subtraction, another important addition in DELPHES3, >>>added * the workflow is neither specific and accurate >>> the diagram includes all the major components of Delphes workflow. * the figure is cut on its right part >>> the figure is fine, the referee probably uses a non-standard PDF viewer. * the caption lacks a complete discussion >>> added PAGE 12 Figure 2 is yet another illustration of the same problem: * there is no explanation of what is the grey band in the right plot >>> the grey band are the error bars. This has been changed in the present version. * there is not explanation of why there is no grey band in the left plot * the caption lacks a discussion >>> added discussion in the caption. As the suggestion is to remove the section altogether, no further comment is made in this report about it.